HVAC INVERTER
HOME / PRODUCTS / AUXILIARY CONVERTERS
HVAC INV BB-35V-5F
Stand-alone or HVAC integrated Installation
The LRV BB‐35V‐5F is specifically designed for Rail Vehicles working under 600Vdc or 750Vdc catenaries. Its design allows to accept a very‐wide Input voltage range from 370Vdc to 930Vdc.
The dual 400V 3phase Output is available even at lowest Input voltage, and is configured as 35kVA VVVF and 5kVA FVFF, but different combinations are possible within the 40kVA power range.
The compact and low weight APS can be installed stand‐alone unit or integrated within the HVAC container. The LRV BB‐35V‐5F is cooled by 2 small / low‐airflow DC blowers (supplied by battery voltage) allowing for very low noise operation and for reduced maintenance/cleaning requirements.
The Output is not galvanically insulated from the Input, but features a full 4kV insulation level. The APS includes a precharging circuit, a full input filter and 2 independent sine output filters.
- Technical Data
- Dimensions
Input Voltage
370-930 Vdc
Overall Dimensions
1000x300xH350mm
Insulation (50Hz 1min)
4000V
Installation 1
Integrated in HVAC
VVVF Output voltage AC
150-460Vac 15-60Hz
Weight 1(Kg)
85kg
VVVF Output power
35kVA, 28kW
Installation 2
Stand alone
VVVF Transient power
70kVA 500ms
Weight 2(Kg)
90kg
FVVF Output voltage AC
400 Vac@50Hz
Protection degree
IP55 (excl. air duct)
FVVF Output power
5kVA, 4kW
Operating Temp. (ºC)
‐25ºC to +45ºC
VVVF Transient power
10kVA 500ms
Noise emission
<65 db at 1m
Overall Efficiency
>90%
Power Connections
Cables
Shock & Vibration
IEC 61373
Control Connections
Harting connector